Clinical Decision Support (CDS) for Outpatient Radiology Imaging

How to cite

Finkelstein, Amy; Bruce Darrow, MD, PhD; Doyle, Joseph; Feeney, Laura; Joseph Kannry, MD; Mazumdar, Madhu; David S. Mendelson, MD, FACR; Shapiro, Jesse. 2015. "Clinical Decision Support (CDS) for Outpatient Radiology Imaging." AEA RCT Registry. AEARCTR-0000905. https://doi.org/10.1257/rct.905-8.0

Download: BibTeX · RIS — for reference managers without a browser translator. Zotero and most others pick up this page's citation metadata directly.

Amy Finkelstein* , Bruce Darrow, MD, PhD , Joseph Doyle , Laura Feeney , Joseph Kannry, MD , Madhu Mazumdar , David S. Mendelson, MD, FACR , Jesse Shapiro

* Primary investigator

Registry ID
AEARCTR-0000905
DOI
https://doi.org/10.1257/rct.905-8.0
First registered
Last updated
Status
Withdrawn
Trial dates
2015-03-21 – 2016-05-16
Countries
United States of America (New York)
JEL codes
I10, I18
Secondary IDs
JPAL-3872
Registry record
http://www.socialscienceregistry.org/trials/905

Abstract

The goal of the study is to determine whether clinical decision support (CDS) for outpatient radiology affects the number, type, or appropriateness of targeted high-cost radiology images (i.e. MR and CT) ordered. The CDS will be delivered to outpatient physicians in the Mount Sinai Health System in New York City. It will be delivered in Epic, an industry-standard electronic medical record software, through ACRSelect, which is a leading decision support tool based on the American College of Radiology (ACR) Appropriateness Criteria (see http://www.acr.org/Quality-Safety/Appropriateness-Criteria), and presents the ACR appropriateness scores for each image on a scale of 1-9 with 1-3 labelled as ‘usually not appropriate’, 4-6 ‘May be appropriate’, and 7-9 ‘usually appropriate’.

Intervention

Treatment group providers will receive Clinical Decision Support at the time of ordering CT or MR images. A pop-up screen providing CDS will appear at physician sign-off for all CT or MR scans scored 1-3, and scans scored 4-6 for which an alternative scan scored 7-9 exists.
This screen will show the appropriateness score of the original scan order, and will display any alternative scans that are scored 7-9 for the same indications and patient characteristics. It will also display a link to relevant ACR documentation relevant to the selected scan and indication.
Any time the pop-up alert appears, a checkbox removing the selected scan from unsigned orders will be checked by default.

Experimental design

Inclusion criteria:
• Outpatient medical provider with scan ordering permissions at Mount Sinai Hospital or Mount Sinai Queens
• Has an active ID in the Epic electronic medical record ordering system

Exclusion criteria:
• Opted out of the study prior to October 13, 2015

Providers were randomly allocated equally into treatment or control groups with no stratification.

Design details

Randomization method
Randomization done in office by a computer (Stata)
Randomization unit
Visiting provider (individual)
Clusters
2038 providers
Observations
2038 providers
Arms
1019 control, 1019 treatment
Primary outcomes
Primary Outcome Measure: • Number of "non-advised" scans ordered per visiting provider [Time Frame: first 365 days after CDS is turned on for the treatment group] [Safety Issue: No] "non-advised" scans are (a) all magnetic resonance (MR) or computed tomography (CT) scans that ACR Select rates 1-3 ("usually not appropriate"), and (b) all MR or CT scans rated 4-6 ("may be appropriate") for which an alternative scan (MR, CT, or other modality) rated 7-9 ("usually appropriate") exists Secondary Outcome Measures: • Number of scans ordered per visiting provider that ACR Select rates 1-3 ("usually not appropriate") [Time Frame: first 365 days after CDS is turned on for the treatment group] [Safety Issue: No] includes magnetic resonance (MR) and computed tomography (CT) scans scored by ACR Select • Number of scans ordered per visiting provider that ACR Select rates 4-6 ("may be appropriate") for which an alternative scan (MR, CT, or other modality) rated 7-9 ("usually appropriate") exists [Time Frame: first 365 days after CDS is turned on for the treatment group] [Safety Issue: No] includes magnetic resonance (MR) and computed tomography (CT) scans scored by ACR Select

Cited by

No citation data available for this registration yet.

Keywords