Pollution and Cognitive Performance: A Field Experiment in High Schools

How to cite

Palacios, Juan; Kok, Nils; Bogaard, Mariët. 2025. "Pollution and Cognitive Performance: A Field Experiment in High Schools." AEA RCT Registry. AEARCTR-0016324. https://doi.org/10.1257/rct.16324-2.0

Download: BibTeX · RIS — for reference managers without a browser translator. Zotero and most others pick up this page's citation metadata directly.

Juan Palacios* , Nils Kok , Mariët Bogaard

* Primary investigator

Registry ID
AEARCTR-0016324
DOI
https://doi.org/10.1257/rct.16324-2.0
First registered
Last updated
Status
In development
Trial dates
2025-06-08 – 2028-01-01
Countries
Netherlands (Limburg)
JEL codes
Q53, I21, C93
Registry record
http://www.socialscienceregistry.org/trials/16324

Abstract

Poor indoor air quality has been increasingly linked to adverse health outcomes and diminished cognitive performance, yet evidence on effective and scalable interventions remains limited. This study investigates the causal impact of indoor air pollution removal on academic performance among high school students in a region historically exposed to elevated pollution levels. Leveraging a randomized controlled trial across secondary schools, we deploy high-efficiency air filtration devices and real-time air quality sensors during standardized exam weeks. Treatment classrooms receive active air filtration prior to and during testing, while control classrooms remain untreated, with some assigned to a placebo condition involving inactive devices. Treatment is randomly assigned within parallel class pairs (same school, year, track), ensuring internal validity and minimizing contamination. Environmental data collected from both treatment and control classrooms will be used to quantify differences in particulate matter concentrations (PM₂.₅ and PM₁₀), while student test scores will serve as the primary outcome of interest. By combining high-frequency environmental monitoring with administrative academic performance data, this project provides policy-relevant evidence on the role of indoor environmental interventions in improving educational outcomes and human capital formation.

Intervention

The core intervention in this study consists of the deployment of high-efficiency particulate air (HEPA) filtration units in middle school classrooms. The primary objective is to remove fine particulate matter (PM) from the indoor environment in a controlled and replicable manner, thereby isolating the causal effect of improved air quality on student academic performance.

Experimental design

The full-scale study employs a randomized controlled trial (RCT) design to estimate the causal impact of improved indoor air quality on student academic performance. The intervention consists of the deployment of 20 HEPA air filtration machines across a sample of 40 classrooms in five Dutch secondary schools during two scheduled exam periods in the 2025/2026 academic year. Randomization is conducted at the classroom–grade–track level, ensuring that for every treated classroom, there exists a parallel control classroom within the same school whose students follow the same curriculum and take the same exams during the testing period. This design allows for precise within-school comparisons and strengthens the internal validity of the estimated treatment effects.

Design details

Randomization method
Randomization done by a computer
Randomization unit
Classroom
Clusters
There will be 40 classrooms in the final experiment.
Observations
The study targets approximately 5,000 students, each completing three standardized tests in two separate exam rounds, yielding a total of 30,000 student-test observations.
Arms
There will be 20 classrooms in the treatment and 20 classrooms in the control.
Primary outcomes
The primary outcomes of interest in this study are student academic performance in standardized exams and indoor air pollution levels PM2.5.
Secondary outcomes
The secondary outcomes in this study are designed to assess whether the air filtration intervention had unintended consequences on other indoor environmental conditions that may affect student well-being, test-taking experience, or the validity of the academic performance measure. These outcomes include: Indoor noise levels (dB) Carbon dioxide concentrations (CO₂, ppm) Temperature (°C) Relative humidity (%) PM\textsubscript{10} concentrations (μg/m³) TVOCs (Total Volatile Organic Compounds, ppb)

Cited by

No citation data available for this registration yet.

Keywords