energy saving of public buildings

How to cite

song, yi. 2024. "energy saving of public buildings." AEA RCT Registry. AEARCTR-0013870. https://doi.org/10.1257/rct.13870-1.0

Download: BibTeX · RIS — for reference managers without a browser translator. Zotero and most others pick up this page's citation metadata directly.

yi song*

* Primary investigator

Registry ID
AEARCTR-0013870
DOI
https://doi.org/10.1257/rct.13870-1.0
First registered
Last updated
Status
On going
Trial dates
2024-07-01 – 2024-10-31
Countries
Private
Registry record
http://www.socialscienceregistry.org/trials/13870

Abstract

Public buildings are a significant source of energy consumption in China and have long faced issues such as poorly managed energy systems. Improved and automated control of air conditioning systems in these buildings can effectively reduce energy waste. However, if occupant behavior is not adequately considered, it can negatively impact their acceptance of newly developed technologies, thereby hindering the achievement of energy conservation goals. By taking into account policy standards regarding air conditioning temperature requirements, we implement various energy-saving strategies and conduct randomized controlled experiments in several public buildings in China. We collect high-frequency data to analyze the impact of different energy-saving strategies on energy consumption as well as user experience. The research results can support efficient energy management and decarbonization in the building sector.

Intervention

The interventions applied to the experimental group include setting a maximum temperature limit, establishing temperature monitoring intervals, and scheduling automatic shutdowns. In contrast, the control group had no interventions and allowed users to fully control their air conditioning usage.

Experimental design

This study was conducted in 17 public buildings in Hubei Province, China, with more than 450 offices, each equipped with an air conditioner. These public buildings are primarily government units, and the office personnel are staff members from various departments. Each air conditioner was installed with a smart controller, available in two versions, which were then connected to energy management platforms. Researchers implemented control strategies, while office staff could also control the air conditioning through remote controls. The study included one control group and five experimental groups, each with different temperature restrictions and adjustment intervals.

Design details

Randomization method
Randomization done in office by a computer
Randomization unit
individual randomization for each building
Clusters
17 public buildings
Observations
about 470 office rooms
Arms
75 rooms control, 70~85 rooms for each experimental group
Primary outcomes
energy consumption; operating duration; air conditioning temperature; user adjustment frequency; adjustment amplitude; number of devices offline; number of user complaints; and number of samples with intervention cessation.
Secondary outcomes
air conditioning wind speed; air conditioning mode

Cited by

No citation data available for this registration yet.

Keywords